Pangh B, Khabaz R, Izadpanah A. Measurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimeters. ijhe 2019; 12 (3) :397-408
URL:
http://ijhe.tums.ac.ir/article-1-6088-en.html
1- Department of Physics, Faculty of Sciences, Golestan University, Gorgan, Iran
2- Department of Physics, Faculty of Sciences, Golestan University, Gorgan, Iran , r.khabaz@gu.ac.ir
Abstract: (2700 Views)
Background and Objective: Human external exposure to natural radiation sources is much more than artificial radiation sources. In this study, external annual effective doses were estimated in cities of Gorgan and Bandar-Torkman by determining ambient gamma dose rate in indoor and outdoor spaces.
Materials and Methods: Using an ionization chamber detector, the outdoor and indoor ambient gamma dose rate at 32 and 16 selected stations in Gorgan and Bandar-Torkman cities was measured for one hour, respectively. Indoor measurements were performed by 36 dosimeters in Gorgan and Bandar-Torkman cities in 11 and 6 residential buildings respectively using thermoluminescence dosimetry method.
Results: The results of this study indicate that the ambient gamma dose rate in outdoor is a little more than this quantity in indoor space. The annual effective dose received by residents of Gorgan and Bandar-Torkman were 0.720 and 0.719 mSv, respectively.
Conclusion: The annual effective dose received by residents of Gorgan and Bandar-Torkman cities is less than the worldwide average, and it is also less than the reference dose level for ordinary people (1 mSv).
Type of Study:
Research |
Subject:
General Received: 2018/06/7 | Accepted: 2019/10/12 | Published: 2019/12/21