Volume 3, Issue 1 (3 2010)                   ijhe 2010, 3(1): 47-58 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Hashemi H, Amin M, Bina B, Movahedian Attar H, Farrokhzadeh H. Survey on possibility of Disinfection of Isfahan North Wastewater  Treatment Plant Effluent by Low and Medium Pressure Ultraviolet Systems in Pilot ScaleSystems in Pilot Scale. ijhe 2010; 3 (1) :47-58
URL: http://ijhe.tums.ac.ir/article-1-134-en.html
Abstract:   (10891 Views)

Backgrounds and Objectives:Today, due to health, environmental and economical problems, of chlorine application, UV radiation is better option than chlorine for disinfection of effluent. The aim of this study was disinfection of secondary effluent with UV radiation.
Materials and Methods: Two types of UV disinfection system including low pressure (LP) and medium pressure (MP) was used to disinfection of Isfahan North Wastewater Treatment Plant (INWWTP) effluent without pretreatment. Single and combined lamps were operated to evaluate the removal of total and fecal coliforms (TC and FC), and fecal streptococcus (FS). TSS, iron, hardness, UV absorption and transmittance were analyzed in order to observe the fouling of the quartz sleeves.
Results: After using LP lamp with dose of 161 mws/cm2, TC and FC content was declined to standard level (1000 TC, and 400 FC/100ml). In addition, disinfection with MP lamp was led to FS content of 400 MPN/100 mL. Combination of LP and MP, with dose of 460 mws/cm2 could be met the environmental requirements of TC & FC, and the FS count was reached to 400 MPN/100 mL with dose of 237 mws/cm2. Maximum photo-reactivation percentage of coliforms after LP and MP lamps were appeared 15 and 3 percent respectively, while it was not observed for FS.
Conclusion: High fluctuation in secondary effluent quality of INWWTP mainly TSS concentration was caused to decline of the UVT value. Therefore, disinfection of effluent by LP, MP and even combined both systems are not applicable in conventional UV dose. Hence, using advanced process unit before UV disinfection system is necessary for removal of TSS.

Full-Text [PDF 1175 kb]   (3651 Downloads)    
Type of Study: Research | Subject: General
Received: 2009/11/20 | Accepted: 2009/12/28 | Published: 2013/07/7

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb