Volume 9, Issue 4 (3-2017)                   ijhe 2017, 9(4): 457-470 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Nabizadeh Nodehi R, Mesdaghinia A, Nasseri S, Hadi M, Soleimani H, Bahmani P. Analysis of Water Corrosion Tendency in Water Supply System Using Qualitative Indices and Calcium Carbonate Precipitation Potential index. ijhe 2017; 9 (4) :457-470
URL: http://ijhe.tums.ac.ir/article-1-5720-en.html
1- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
2- Center for Water Quality Research (CWQR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
3- Center for Water Quality Research (CWQR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran , hadi_rfm@yahoo.com
4- Environmental Health Engineering, Kurdistan Rural Water and Wastewater Company, Sanandaj, Iran
Abstract:   (6759 Views)

Background and Objective: Water corrosion and scaling are known as destructive phenomenon of drinking water quality and water facilities. In this study, the groundwater tendency to corrosion or scaling in source water, water storage reservoirs and distribution system were studied. Simultaneous use of some qualitative and a quantitative index along with statistical analyses to assess the water scaling or corrosion tendency were investigated.

Materials and Methods: The data analysis of groundwater, water storage reservoirs and water distribution system in rural area of Kurdistan province were analyzed and the amount of Langelier (LI), Ryznar (RY), Pockorius (PSI) and Larson–Skold (LS) and CCPP indices were determined. Corrosion and scaling threshold for qualitative indices were determined based on CCPP index. The mean of indices was compared with the thresholds using independent t-test. ANOVA was used to assess the difference between the indices in different sources of water.

Results: The balance range for LI, RY and PSI found to be -0.1-0.05, 7-9 and 7.1-8.5. The mean CCPP for groundwater, reservoirs and networks were 9.27 ± 1.29, 9.13 ± 1.25, 11.25 ± 1.23, respectively. All three sources of water have some tendencies toward scaling; however, a significant balance status was confirmed statistically. According to Larson–Skold index, sulfate and chloride anions did not play a role in scaling process.

Conclusion: The use of qualitative indices with CCPP index can provide more accurate estimation of water tendency toward scaling or corrosion. The assessment of qualitative indices along with CCPP is recommended in drinking water corrosion monitoring studies.

Full-Text [PDF 1300 kb]   (4844 Downloads)    
Type of Study: Research | Subject: WATER
Received: 2016/05/29 | Accepted: 2017/02/12 | Published: 2017/03/5

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb