Volume 7, Issue 2 (10-2014)                   ijhe 2014, 7(2): 253-264 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Rahmani A, Mehralipoor J, Shabanlo A. Investigation of Electro-Fenton process in degradation of phenol from aqueous solutions. ijhe 2014; 7 (2) :253-264
URL: http://ijhe.tums.ac.ir/article-1-5035-en.html
1- Department of Environmental Health Engineering, Faculty of Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
2- Department of Environmental Health Engineering, Faculty of Health, Hamadan University of Medical Sciences, Hamadan, Iran
3- Department of Environmental Health Engineering, Faculty of Health, Hamadan University of Medical Sciences, Hamadan, Iran , shabanlo_a@yahoo.com
Abstract:   (8041 Views)

Background and Objective: Electrochemical methods as one of the advanced oxidation processes (AOPs), have been applied effectively to degrade recalcitrant organics in aqueous solutions. In the present work, the performance of electro-Fenton (EF) method using iron electrodes on the degradation of phenol was studied. Materials and Methods: In this study, a lab-scale EF batch reactor equipped with four electrodes and a DC power supply was used for removing phenol. The effect of operating parameters such as pH, voltage, H2O2 and initial phenol concentration and operating time were evaluated. We added H2O2 manually to the reactor while iron anode electrode was applied as a ferrous ion source. Results: It was found that initial pH of the solution, initial H2O2 concentration, applied voltages were highly effective on the phenol removal efficiency in this process, so that 87% of phenol after 15 min of reaction at pH=3.0, voltage 26 V and H2O2 100 mg/L was removed. Phenol removal efficiency decreased with increasing pH, so that at pH 10, after 15 min, efficiency was 11%. To remove 99.99% phenol at pH 3, 100 mg/L concentration of H2O2 and voltage 26 V for 60 min was required. Conclusion: Electro-Fenton process using iron electrodes for phenol degradation and remediation of wastewater could be a promising process.

Full-Text [PDF 2092 kb]   (3905 Downloads)    
Type of Study: Applicable | Subject: wastewater
Received: 2013/07/20 | Accepted: 2013/12/5 | Published: 2015/02/15

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb